Marlstone Works
Shelter systems · partner programme

Case · California & the western US

Wildfire smoke

A clean-air refuge and somewhere to wait for rescue. If an evacuation order is issued and the road is open, the correct action is to leave — and we say that before we say anything else.

SH-00 · REV 1.0Issued 2026-09-20Gates 0 / 7Construction Not authorised
TOPSOIL / ENGINEERED FILLSTIFF CLAYSAND & GRAVEL — PERCHED WATERWEATHERED ROCKROCKGRADE ±0.00−0.0−4.0−8.0−12.0−16.0−20.0mM02DECONM04LIVINGM06MEDICALM07AIRM10POWERM22FIRE CTLM20REFUGE2 × GENM01ENTRANCECREDIBLE COLLAPSE ZONEOF THE SURFACE STRUCTUREM14REMOTE EXITSEPARATE SHAFTDIFFERENT COLLAPSE ZONEMECHANICAL RELEASE, NO POWERPROTECTED INTAKEBLAST VALVE · ISOLATION DAMPERLOCAL ENCAPSULATED LEADBY SOURCE-TERM CALCULATION · NOT A BLANKETEARTH COVER — BY SITE CALCULATIONKEYNOTES01Two exits, different shafts, different collapse zones02Manual release on every protective door, with no power03Air path: filters always, manual crank included04Depth, thickness, shielding: calculated, not cataloguedNOT FOR CONSTRUCTIONCONCEPT STAGE · GATES G0–G6 OPENSCHEMATIC SECTION · S3 MASTER · NOT TO SCALE · INDICATIVE ARRANGEMENT ONLY · REV 1.0
SchematicS3 master · not to scale · indicative arrangement only
CW-01The hazard

If the order comes and the road is open, you leave.

Clean-air refuge — flame immersion excluded

That sentence is the design basis, not a disclaimer at the foot of a brochure. This product is a filtered, monitored clean-air refuge and a place to wait for rescue. It is not a structure to ride a fire front out in, and an agent who lets a Californian believe otherwise has created a fatality risk we will not carry.

CAL FIRE's position first, and then ours

CAL FIRE's evacuation guidance is to leave as soon as evacuation is recommended by fire officials, to avoid being caught in fire, smoke or road congestion — and not to wait to be ordered out. Leaving early also keeps roads clear for engines, and in an intense fire crews may not have time to knock on every door. (CAL FIRE — Go Evacuation Guide)

Nothing we sell changes that. A shelter is for the narrower case where the road closed before the household moved, or where the exposure is smoke rather than flame and there is nowhere useful to drive to. If a prospect is buying this so that they can stay, the correct commercial response is to lose the sale.

We publish this first because it is the part of the conversation a competitor moves to the end. It is also the part that a fire chief, a plan checker and a claims adjuster will each test you on, separately, and none of them will tell you they are testing.

Acreage is a land-management statistic. Structure loss is the exposure statistic. California burned roughly half as many acres in 2025 as in 2024 and lost about nine times as many structures. An agent who builds a territory case on acreage totals will look weak in exactly the years that matter most, because a low-acreage year can be a catastrophic structure year when fire runs through an interface neighbourhood instead of a watershed.

Smoke reaches orders of magnitude more households than flame does. The Stanford analysis of smoke-specific PM2.5 found that the number of Americans living where the air reached at least 100 µg/m³ from wildfire smoke on at least one day a year rose roughly 27-fold between 2006–2010 and 2016–2020, from under half a million to over eight million (Stanford / Childs et al., Environmental Science & Technology).

California's Legislative Analyst's Office reports the same shape from the regulatory side: in the study it cites, on days that exceeded the federal PM2.5 standard, wildfire contributed on average more than 70% of total daily PM2.5, against about 12% across the whole study period (LAO — Living Under Smoky Skies). Smoke is no longer an episode inside an otherwise improving air-quality trend. In the western states it is the trend.

And the reason this buyer is actually calling is usually the insurance letter. The California FAIR Plan — the state's insurer of last resort — reported 696,562 policies in force and about USD 768 billion of exposure as at June 2026, up roughly 157% and 250% respectively since September 2022. Nearly every one of those policies exists because a private carrier declined or did not renew. A household reads that letter, searches for something it can actually do, and lands on a page like this one.

16,512Structures destroyed in California in 2025, against 525,223 acres burned across 8,036 fires — roughly half of 2024's acreage and about nine times its structure lossCAL FIRE incident archive, as compiled at 2025 California wildfires. Comparators from the same archive: 2024 — 8,110 fires, 1,077,711 acres, 1,837 structures; 2026 to 16 September — 5,434 fires, 322,211 acres, 143 structures. Re-pull current-year figures from CAL FIRE before quoting them; a season total is not final until the season closes.
≈4.97MEST. — California housing units inside the wildland-urban interface; plausible band 4.0M – 5.5M. Assumptions and arithmetic below.Our estimate: 15,064,131 California housing units at 1 January 2026 (CA Department of Finance, E-1) × assumption A1 of 33%. Anchored on US Forest Service research placing more than 44 million homes, about 32% of US housing, inside the WUI (USFS, data to 2020). Published California-specific WUI housing counts cluster near 5 million; re-derive the count for your own counties from the SILVIS WUI layer before using it commercially.
696,562California FAIR Plan policies in force as at June 2026 — about 157% more than September 2022, with roughly USD 768 billion of exposure behind themReported from FAIR Plan disclosures; the plan publishes its own key statistics and data, and the Assembly Insurance Committee's FAIR Plan oversight hearing background paper, 28 January 2026 sets out the growth. These figures move monthly — re-pull the current month before you put a number in front of a customer.
+29.1%Average rate increase approved on the FAIR Plan dwelling line, effective 15 October 2026, against 35.8% requested — the wildfire component carries most of itCalifornia Department of Insurance prior-approval decision on the California FAIR Plan dwelling rate filing. A rate decision is a dated document, not a standing fact — verify the approved figure and its effective date against the Department's own filing record before you repeat either number to a customer. See the department's Sustainable Insurance Strategy for the wider reform package, which pairs catastrophe modelling and California-only net reinsurance cost in rate filings with a carrier commitment to write 85% of statewide market share in wildfire-distressed ZIP codes. We are not insurance advisers; this is context, not advice.
27×Increase in the number of Americans living where wildfire-smoke PM2.5 reached at least 100 µg/m³ on at least one day a year, 2006–2010 compared with 2016–2020Stanford Doerr School — Childs et al., Environmental Science & Technology, September 2022. This is a national figure; the western states carry most of it, and the study also reports a far larger multiple off a far smaller base above 200 µg/m³.
>70%Wildfire's average share of total daily PM2.5 in California on days that exceeded the federal standard, in the study the LAO cites — against about 12% across the whole periodLegislative Analyst's Office — Living Under Smoky Skies: Understanding the Challenges Posed by Wildfire Smoke in California. The LAO also records California wildfire PM2.5 emissions of roughly 380 Gg in 2018 and 1,070 Gg in 2020, against about 136 Gg a year on average across 2011–2020 excluding the severe years.
≈109/yrEST. — plausible California unit demand in steady state, band ≈55–219 a year. A small, slow, high-liability market. Read it honestly.Our estimate — the five-step funnel in the table below, built from the CA Department of Finance housing base and four stated assumptions. Every step is an assumption you should challenge with your own county data. We would rather hand you a visible assumption than an invisible one.
California fire years, hard data in every column. Note what happens between the acreage column and the structures column.
YearFiresAcres burnedStructures destroyedDeaths
20248,1101,077,7111,8371
20258,036525,22316,51231 (prelim.)
2026, to 16 September5,434322,2111431
The market funnel — one hard row and five assumed rows. Challenge the assumed ones with county data before you plan a territory around them.
StepWhat it countsBasisFigure
Step 0California housing units, 1 January 2026Hard data — CA Department of Finance, E-115,064,131
Step 1Inside the wildland-urban interfaceAssumption A1 — 33%, band 27–37%, anchored on the USFS national share of about 32%≈4,971,000
Step 2High-hazard subset — High or Very High Fire Hazard Severity ZoneAssumption A2 — 25%, band 15–35%≈1,243,000
Step 3Physically feasible sites — detached, owner-occupied, lot space, plant access, and not excluded by floodway, landslide or a burned catchmentAssumption A3 — 55%, band 40–70%≈684,000
Step 4Financially capable of a six-figure discretionary resilience purchase without finance stressAssumption A4 — 8%, band 5–12%≈54,700
Step 5Converting over a ten-year window, absent a step change in permitting or agency doctrineAssumption A5 — 2%, band 1–4%≈1,090 units / ≈109 a year

The arithmetic, in the open. Step 0 is hard. Step 1 is the weakest assumption on this page: there is no single authoritative count of California dwellings inside the WUI, and anyone who quotes one to you without showing their working is guessing. Step 2 narrows to the hazard classes that carry legal consequence — and the 2025 Fire Hazard Severity Zone update reclassified an estimated 1.2 to 1.4 million additional acres statewide into High or Very High inside Local Responsibility Areas, so this denominator is still moving (OSFM).

Step 3 is where our own gate criteria bite, not the market's. A mapped floodway, a FEMA Zone V or mapped Coastal A location, a landslide zone, a burned catchment upslope, or a parcel a fire engine cannot reach are each a No-Go or relocate condition under our own rules. That is a large deduction and it is deliberate. Step 4 is an income screen. Step 5 is the honest one: permit friction, agency doctrine that says leave, and competition from far cheaper mitigation that does more per dollar.

Read the output honestly. Roughly 109 units a year across the whole state is not a category anyone should staff a showroom for. A single territory should plan for low single-digit to low double-digit units a year in normal conditions, with enquiry spiking sharply for twelve to twenty-four months after a destructive season and after each insurance non-renewal cycle — and with conversion improving only where a permit path already exists and a California-licensed engineer is willing to seal the drawings.

The same logic travels north and east, with different denominators. Oregon, Washington, Colorado and Idaho all carry interface exposure, and each arrives with its own fire authority, its own code adoption and its own insurance market. We do not print their season totals here: a season figure we have not pulled from the issuing agency ourselves is a number we would be asking you to trust instead of check, and this page does not trade in those. Rebuild the funnel for the state you are actually selling into — housing base from that state's own demographic series, hazard classification from its own mapping, season figures from the National Interagency Fire Center statistics or the state forestry agency. The hazard is regional. The code, the fire authority and the insurance market are not.

Why these numbers are on this page, and how they may not be used

They are here to explain why the code and the insurance market look the way they do, and to size a market honestly. They are not motivating imagery. No page, brochure, advertisement or agent script we produce may name a real fire, use its death toll, or describe the people who died in it in order to move a unit. An event is evidence about rules and about probability. It is never a threat pointed at a prospect, and an agent who inverts that has broken the distribution agreement rather than bent a style guide.

CW-02What harms people

The flame front is not what reaches most households

The buyer arrives with an image of a wall of fire at the window. That image is real, and it is also the least common of the four things that actually put a wildland-urban interface household in danger. Selling against the image instead of against the evidence is how a vendor ends up building the wrong product for the right customer.

First: embers, not radiant flame, are the dominant structure-loss pathway. Wind-driven embers land in gutters, under decks, against fences and in the first few feet of a house hours before or after a front passes, and the house ignites from its own surroundings. That is the entire reason California built a five-foot ember-resistant zone into law. It is also why the highest-value dollar a WUI household can spend is almost always on the house envelope and the first five feet, not on a refuge.

Second: smoke arrives at households that flame never reaches, and it stays for days. A household two counties away from the fire perimeter can spend a fortnight indoors at concentrations that public-health agencies treat as unhealthy. This is the exposure our product is actually designed against, and it is the honest reason a clean-air refuge is a defensible purchase in the first place.

Third: the power goes off, and it goes off on exactly the wrong days. Californian utilities de-energise circuits during extreme fire weather. The CPUC's own framing is that while shutoffs may reduce wildfire risk, they leave communities and essential facilities without power, which brings its own risks and hardships, especially for vulnerable people (CPUC — Public Safety Power Shutoffs). A public-safety power shutoff removes the air cleaner, the HVAC fan, the well pump, the medication refrigerator, the oxygen concentrator and the CPAP on the day the air is worst.

Fourth, and this is the one that kills: the response to the third problem. A household without power drags a portable generator closer to the house, or into the garage, because the cable is short and the smoke is outside. CPSC data attributes an average of about 100 deaths a year in the United States to carbon monoxide from portable generators, with an estimated 858 non-fire CO deaths associated with portable generators since 2011 — about 42% of consumer-product non-fire CO deaths in its jurisdiction (CPSC).

What the buyer assumes, what the evidence shows, and what it means for where their money should go
Harm pathwayWhat the buyer assumesWhat the evidence showsWhere the money should go
Ember ignition of the dwellingA flame front arrives and burns the house down in one passEmbers ignite the house from its own immediate surroundings, often before or after the front. California legislated a five-foot ember-resistant zone in response.Roof, vents, glazing, decking, and clearing the first five feet. Cheap relative to anything on this page and it protects the asset, which a refuge does not.
Smoke exposure over days to weeksA nuisance; close the windows and waitThe exposure reaching by far the most households, at concentrations agencies treat as unhealthy, with wildfire contributing the majority of daily PM2.5 on exceedance days in the study the LAO citesA cleaner-air room, and then — for a household that genuinely needs more — a sealed, filtered, monitored refuge. This is the product.
Public-safety power shutoffAn inconvenience that a generator solvesIt removes the air cleaner, the HVAC fan, the well pump, refrigerated medication and powered medical equipment on the highest fire-weather days, which are also the highest smoke daysStored energy sized to the life-safety load, with the life-safety loads on their own priority tier — not a comfort-led generator sizing exercise
Carbon monoxide from the household's own responseNowhere on the buyer's listCPSC attributes an average of about 100 US deaths a year to portable-generator CO, and about 42% of consumer-product non-fire CO deaths since 2011No combustion source inside the refuge, an intake that can be shut, and CO monitored continuously with an alarm that does not depend on the network
Deciding to leave too lateThere will be time, and a warningCAL FIRE's guidance is not to wait for an order, because road congestion, smoke and fire behaviour remove the option faster than people expect and crews may not reach every doorA written leave trigger, a second route off the property, and a household that has rehearsed both. This costs nothing and outranks every product decision below it.
The PSPS chain, in the order a household experiences it
  • Extreme fire weather is forecast. The utility issues advance notice and then de-energises circuits. Post-event reports for individual 2025 events range from a few hundred customers to tens of thousands, and restoration follows patrol and repair — not the end of the wind event.
  • Grid power stops. The portable air cleaner in the cleaner-air room stops with it, at the moment the outdoor air is at its worst.
  • The HVAC fan stops, so a MERV 13 or higher central filter stops moving air through the filter. A filter with no fan behind it is a piece of pleated paper in a duct.
  • In rural interface parcels, the well pump stops. Water pressure falls, and with it any notion of using domestic water for fire defence.
  • Refrigerated medication warms. Powered medical equipment — oxygen concentrators, CPAP, nebulisers, powered mobility — runs on whatever battery it happens to have. This is the single most legitimate fit signal on this page.
  • Cell sites run on their own backup and then degrade. Notification, which the household was relying on for its leave decision, becomes less reliable at exactly the wrong time.
  • Someone moves a generator closer to the house. See the note below.
This is the one we design against hardest, and it is not the one the buyer asks about

A sealed room plus a combustion engine is a fatal combination, and the sealing makes it worse rather than better. Our baseline therefore places no combustion source inside the occupied volume at any tier, requires continuous CO, CO₂, O₂, temperature, humidity and smoke monitoring in even the basic product, and requires the alarm path to work without the network and without the site's automation. Any engine-driven generator sits outside, with its exhaust routed and its position checked against the intake by the mechanical designer, not by the homeowner with an extension lead.

Say this to the customer early. It reframes the product from a fantasy object into a piece of mechanical equipment with a stated failure mode, and it is the moment a serious buyer starts trusting the conversation.

The honest ranking of spend, which costs us sales and earns us referrals

First, a written leave trigger and a rehearsed second route off the property: free. Second, Zone 0 and envelope hardening — roof, vents, glazing, decking, and clearing the first five feet: low thousands to low tens of thousands, and it protects the house as well as the people. Third, a CARB-certified portable air cleaner sized to the room, per US EPA cleaner-air-room guidance: a few hundred dollars. Fourth, and only fourth, an engineered clean-air refuge. A household that has not done the first three is not ready for the fourth, and an agent who sells it to them anyway has sold the most expensive item on the list to solve the least likely problem.

CW-03What it does

Filtered air, watched numbers, nothing burning inside, two ways out

Everything below is mechanical and checkable. Where a number would be invented, it says TBD or by site calculation, and it will keep saying that until a geotechnical report, a load calculation and a supplier's test documentation exist for your specific site.

The scope, module by module

  • M07 — air life support, mandatory at every tierProtected intake → intake closure device → pre-filter → particulate filter → mechanical supply → controlled exhaust → backflow prevention, held at slight positive pressure with an over-pressure relief device. Filter grade, airflow, final filter resistance, gas-phase media capacity and change interval are TBD, by site calculation — they depend on volume, occupancy, leakage rate and the contaminant the assessment actually identifies.
  • The manual path, which is the part that mattersA hand-crank or equivalent unpowered ventilation path that rejoins the train before the filters, never around them. Measured performance at full occupancy against a loaded filter is a commissioning test, not a brochure claim, and the measured figure is TBD.
  • Monitoring, mandatory even in the basic productContinuous CO₂, CO, O₂, temperature, humidity and smoke monitoring, with a local alarm that works without the network and without the site's automation. Particulate monitoring inside and outside the envelope is how an occupant knows the filter is still working rather than hoping it is.
  • No combustion source insideNo engine, no fuel-burning heater, no cooking flame inside the occupied volume, at any tier. Any engine-driven generator is external, with exhaust routing and separation from the intake set by the mechanical designer.
  • M20 — smoke control and clean-air refugeAn independent smoke-exhaust path, an independent clean-air refuge space, and a short-duration breathing-air reserve. The reserve quantity and duration are TBD, by site calculation — a duration figure we have not calculated for your site would be a number invented to close a sale.
  • M10 — power that survives a shutoffA low-voltage DC life-safety bus and a four-tier load priority. P0 covers air master control, main and backup fans with a local manual start circuit, hand-crank ventilation, the monitoring set, the control necessary for protective doors and isolation valves, DC emergency lighting and minimum internal alarm and communication. P0 loads are not shed because comfort loads exceeded their limit, and when the energy management system fails the distribution system falls to a predefined P0 safe state. Storage capacity and run time are TBD, by site calculation.
  • M13 and M14 — two ways outTwo independent ground-level exits, whose routes do not share a single collapse zone or a single superstructure. Both are mechanically openable from inside without power and without the automation working. If both exits sit under the same structure, you have one exit, and a drawing that shows two is telling you something untrue.
  • Manual backup, without exceptionEvery automated device has a manual fallback. Every external link can be isolated by hand. No single point of failure may immediately leave occupants unable to breathe, drink, dispose of waste, see, communicate or leave. Site automation is never the sole controller of alarm, fire, air, water release or energy.
How this maps onto the public-health guidance a fire chief already believes
  • US EPA cleaner-air-room guidance: keep doors and windows closed, avoid indoor particle sources such as cooking, smoking and candles, and set an HVAC system with a fresh-air option to recirculate or close the intake (EPA).
  • Use a CARB-certified air cleaner, because those produce little or no ozone, and choose a device whose clean air delivery rate for tobacco smoke is at least two-thirds of the room area in square feet (EPA). A California customer should check certification before brand.
  • MERV 13 or higher central filtration where the system is compatible, and increased filter replacement frequency during smoke episodes — both carried in our engineering baseline from EPA and CDC guidance.
  • Follow the orders of your local emergency management agency. Nothing in our documentation overrides an evacuation order, and our owner's manual says so in the same words.
So what does an engineered refuge add over a room with a good air cleaner in it?

Five things, and only five. One, an envelope whose leakage rate is measured at commissioning rather than assumed. Two, an intake that can be closed deliberately, so the room stops being a function of which way the wind is blowing. Three, an atmosphere that is monitored rather than judged by smell, with CO and CO₂ on the same panel as the particulate reading. Four, power arranged so that the fans and the monitoring sit on a priority tier that comfort loads cannot pull down, which is what keeps the room working through a shutoff. Five, a second exit that opens by hand.

That is a real list and it is a short one. If a competitor's list is longer, ask which item on theirs has a commissioning test behind it.

The limits of filtration, stated by us rather than discovered by you

Filters are consumables with a finite life, and wildfire smoke loads them fast. Gas-phase media have a finite capacity for a defined set of compounds under defined conditions; no single filter element removes every substance, and any supplier who says otherwise has told you what their engineering is worth. Replacement intervals shorten during smoke episodes. A filter that is not changed on schedule is not a filter, it is a restriction — and the fan behind it will tell you so through the pressure differential reading long before the occupants notice.

Filter grade, media capacity, final resistance and replacement interval are TBD, by site calculation, and they belong in the owner's manual alongside applicable threats, prohibited uses, maximum occupancy, maximum occupancy duration, maintenance intervals and evacuation conditions.

CW-04What it does not do

The list of things we will not claim

Read before quoting

This is the section a competitor will not publish, and it is the reason to keep reading. Everything below is a threat this product does not address in California today. If any one of them is what you actually need, stop here — you need a different answer, and possibly a different supplier.

Direct flame immersion is excluded from the design basis. Not softened — excluded.

Our engineering baseline states the objective for a basic shelter against wildfire as smoke-clean breathable air and waiting for rescue, not survival of direct flame engulfment. That boundary is not a wording nicety and it is not a negotiating position. Survival of a burnover is a different design problem with a different structural envelope, a different test regime and a different price, and this product has not been assessed against it.

The California Wildland-Urban Interface Code governs the building, not a refuge's performance. The 2025 Title 24 cycle created a standalone California Wildland-Urban Interface Code as Title 24 Part 7, published 1 July 2025 and effective 1 January 2026, into which the State Fire Marshal relocated the ignition-resistant materials and construction provisions previously carried in CBC Chapter 7A, with the corresponding California Residential Code provisions replaced by references to Part 7 (California BSC · ICC — CWUIC 2025). California applies the code in effect when the permit application is filed, so confirm the governing edition with the reviewing jurisdiction rather than asserting it — and do not tell a plan checker what happened to Chapter 7A until they have told you.

FEMA publishes guidance. It does not certify products. Neither does any code body, in this market or any other. A compliance statement is assembled from a test report bound to its standard, edition, laboratory, specimen configuration, installation condition and validity; the seal of a design professional licensed in that state; and acceptance by the Authority Having Jurisdiction. Not at quotation. Not at delivery. Not at installation. At AHJ acceptance — and a safe room is generally not automatically exempt from a building permit merely for being an accessory structure.

Threat matrix — what is in scope subject to assessment, and what is not claimed. The banded rows are the ones we do not claim.
Threat or outcomeClaimed in California?The honest statement
Filtered air against wildfire smoke inside a sealed, monitored envelopeIn scope, subject to assessmentThis is the baseline function, and it maps cleanly onto published US EPA and CDC wildfire-smoke guidance. Filter grade, airflow, media capacity and replacement interval are by site calculation.
A short wait-for-rescue period while sealed, with two exitsIn scope, subject to assessmentOccupant count and maximum occupancy duration are TBD, by site calculation, and belong to the licensed engineer who seals the design. We publish neither figure here, and we will not give one over the phone.
Direct flame contact, flame immersion or burnoverNot claimedExcluded from the design basis of the basic product and not assessed. If this is what the site or the household actually requires, the basic route is void and the requirement returns to the master architecture for redesign.
A reason to stay when an order is issued and the road is openNot claimed — everThis is the one exclusion with a contractual consequence. An agent who implies it has created a fatality risk and a liability we do not accept, and it is a grounds-for-termination clause in any distribution agreement we sign.
Compliance with the California Wildland-Urban Interface Code, Title 24 Part 7Not claimedNo design has been submitted for your site, no California-licensed professional has sealed it, and no jurisdiction has accepted it. Any of those missing means no compliance claim, and every one of the three is missing today.
Discharging the owner's defensible space duty — PRC 4291 and Zone 0Not claimedDefensible space is a continuing vegetation and materials obligation on the property owner. A shelter does not discharge it. Worse, a shelter placed within five feet of a dwelling becomes a Zone 0 object in its own right and must be detailed accordingly.
A burned catchment, mapped floodway, FEMA Zone V, mapped Coastal A, or landslide-liable siteNot claimed — No-GoUnder our own gate criteria this is a No-Go or relocate condition, and FEMA's siting criteria state that safe rooms are not allowed in floodways under any circumstance. We decline the site. Declining is the point of having criteria.
Deep burial as the wildfire answerNot claimedDepth is a conclusion derived from a site, never a marketing number. The basic product's preferred configuration is at-grade or semi-buried, and on a flood-liable California parcel the elevation criteria push it further above grade rather than below it.
Wind or impact performance bound to ICC 500-2023 or FEMA P-320 (2024, 6th ed.)Not claimed on this pageThat is a different hazard with a different design basis and a different tested assembly. It is not carried over here by implication, and an ordinary commercial steel door does not automatically satisfy those wind-pressure and missile-impact requirements.
Blast, radiological, chemical or biological attackNot claimedThe basic product is a subtraction from a master architecture, and those modules are among the things subtracted. Marketing a reduced product as a complete protective installation is prohibited by our own engineering baseline, not merely discouraged.
Long-term self-sufficient occupation off every external linkNot claimedWater storage, waste capacity, fuel inventory, generator capacity and stored energy run time are TBD, by site calculation. A duration figure we have not calculated for your site would be a number invented to close a sale.
A premium reduction, a route off the FAIR Plan, or a carrier returningNot claimedWe found no evidence that a shelter by itself changes a California homeowners rating, and we are not insurance advisers. Ask your carrier in writing before you buy, and keep the permit file. Note the risk running the other way: an unpermitted structure can complicate a claim or a sale.
Numbers we will not guess — for anyone, at any price, in any market
  • Burial depth. Steel or concrete thickness. Lead thickness or shielding equivalence — and the basic product carries no lead, because lead has no core value against smoke.
  • Door pressure rating or impact rating. Ventilation flow rate. Filter capacity and final resistance.
  • Oxygen or breathing-air quantity. Water storage or regeneration capacity. Diesel inventory, generator capacity and stored-energy run time.
  • Well depth and recharge rate. Safe occupant count. Safe occupancy duration.
  • Each of these is TBD or by site calculation. A supplier who answers any of them over the phone, before a survey, has told you what their engineering process is worth.

Fireproof bunker — ride the firestorm out at home.

A sealed, filtered, monitored clean-air refuge with two mechanically openable exits, for the case where the road closed before the household moved. Direct flame immersion is excluded from the design basis.

It contradicts CAL FIRE's own evacuation guidance, which loses the fire authority, the plan checker and eventually the customer. It also creates a fatality risk, which is why it terminates the agreement rather than earning a warning.

Chapter 7A compliant. Meets the California WUI code.

The California Wildland-Urban Interface Code, Title 24 Part 7 (2025 edition, effective 1 January 2026) sets ignition-resistant construction requirements for the building. Whether a specific installation complies is decided by the reviewing jurisdiction, applying the edition in force when the permit application was filed.

A product cannot be code-compliant in the abstract, the code moved between parts in the 2025 cycle, and California applies the edition in force at application. Saying otherwise is the fastest way to lose a plan checker permanently.

FEMA-certified shelter, now available in California.

Designed with reference to published FEMA and ICC guidance where it is relevant to the hazard under discussion. FEMA publishes guidance and does not certify products; compliance is established by test documentation, a licensed design professional's seal and AHJ acceptance.

It is untrue, and it is the phrase most likely to be repeated back to you by a building official who has heard it from three vendors already this year.

Install this and your insurer will come back, or your FAIR Plan premium will drop.

We are not insurance advisers, and we have found no evidence that a shelter by itself changes a California homeowners rating. Get anything you are told about premium impact in writing from the carrier before you buy.

The insurance letter is usually why this buyer called, which makes it the easiest lie to tell and the most damaging one. An unsupported financial claim about an insurance outcome is a regulatory problem for the agent, not only a credibility problem for us.

CW-05Approval route

Who signs what in California, and the two things that kill the site

The steel is not the hard part. The hard part is a sequence of independent people agreeing, each within their own licence, none of whom works for us. An agent who can map this sequence for a prospect is worth more than an agent who can describe a filter.

Going below grade in California brings its own permit, egress and geotechnical problem

A safe room is generally not automatically exempt from a building permit merely because it is an accessory structure. Assume a permit is required and be pleasantly surprised, never the reverse. In-ground work commonly requires drawings sealed by a professional engineer licensed in California, and California is a high-seismic state, so foundation, anchorage, uplift and connection design is not a formality anyone waves through.

Egress is two separate code objects and they are not the same object. Any below-grade space treated as habitable brings the California Residential Code emergency escape and rescue opening provisions into play (CRC R310), while our own baseline independently requires two independent ground-level exits whose routes do not share a single collapse zone or superstructure, both mechanically openable from inside without power. Do not let a customer assume one permit or one opening satisfies both. It does not, and the inspection will say so.

Floodplain is the most common project-killer for anything buried. FEMA's criteria state that safe rooms are not allowed in floodways under any circumstance, and outside the floodway a residential safe room must be sited outside high-velocity wave-action areas and mapped Coastal A Zones unless the Board of Appeals permits otherwise. In Zone A there is an allowable path, but it works by elevating the safe room — which is the opposite move to burying it, and on a flood-liable California parcel that criterion is usually what pushes the product at grade (FEMA — flood hazard siting and elevation criteria for residential safe rooms, November 2024).

A burned catchment changes the parcel for years — and the geotechnical report you already have was written about a different hillside

Wildfire removes vegetation and alters soil properties, which dramatically increases rainfall runoff on steep terrain; soil, ash, wood and boulders are then scoured from hillslopes and channels and can mobilise as damaging debris flows. These are typically triggered by short bursts of intense rainfall, and even modest rainstorms can produce dangerous flash floods and debris flows in steep burned areas (USGS — post-fire debris-flow hazards).

The window is measured in years, not months. USGS research on watershed recovery finds the return period of debris-flow-initiating rainfall rising from roughly one year immediately after a fire toward more than ten years after about four seasons of vegetation regrowth — so the parcel is at its most exposed in the first wet season after the fire and remains elevated for several after that. California runs a dedicated Burned Watershed Geohazards Program and post-fire Watershed Emergency Response Team assessments for exactly this reason.

The commercial consequence for an agent. A household that has just watched the hillside above them burn is precisely the household most likely to call you — and precisely the parcel most likely to be a No-Go for a below-grade refuge this year. A buried room at the bottom of a freshly burned catchment converts a smoke problem into a burial and drowning problem. Say that in week one. Offer to revisit the site after the catchment has been assessed and after vegetation has recovered, and put the revisit date in writing. That sentence loses a deposit and keeps a district.

Step 1

Jurisdiction, code edition, and which authorities you are actually dealing with

Is the parcel in a State Responsibility Area or a Local Responsibility Area, and what did the 2025 Fire Hazard Severity Zone update put it in? Identify every AHJ: building, fire — CAL FIRE or the local fire district, health for septic and well separation, floodplain administrator, and in many counties a separate grading authority. California applies the code in effect when the permit application is filed, so establish the governing edition before you draw anything.

Step 2

Site screening that can end the project — and sometimes should

Mapped floodway. FEMA Zone V or mapped Coastal A. Landslide zone. A burned catchment above the proposed position. Emergency-service access and a turnaround for apparatus. A crane and excavator route that exists in reality and not only on a plan. Any of these can be a No-Go or relocate condition under our own gate criteria, and finding one in week one is worth more to the customer than finding it in month nine.

Step 3

Geotechnical investigation, and hydrogeology wherever the work goes below grade

Typically three to eight weeks, with drill-rig availability, groundwater re-testing and winter access as the usual delays. Nothing downstream — structural design, buoyancy check, anchorage, backfill method — can be sealed without it, and a supplier who quotes a depth before it exists is quoting a number they invented.

Step 4

Local fire authority review, defensible space and the Zone 0 question

Defensible space is a continuing obligation on the owner under PRC 4291 and the Government Code. California's Board of Forestry and Fire Protection adopted emergency Zone 0 regulations on 19 August 2026 under AB 3074, establishing an ember-resistant zone within five feet of qualifying structures, submitted to the Office of Administrative Law on 28 August 2026 and requiring OAL approval before they operate; existing structures phase in over several years and new-structure requirements follow updated Board guidance (Best Best & Krieger summary). Confirm current status and local adoption before advising anyone — and note that a shelter placed within five feet of the dwelling becomes a Zone 0 object itself.

Step 5

Site-specific structural design, sealed by a California-licensed engineer

Foundation, anchorage, uplift and buoyancy with the pumps assumed failed, penetrations, connections and seismic design. Licensure is per-state and must be verified rather than assumed. The engineer who seals this owns the design basis for the site, and the occupancy and duration figures that we decline to publish are theirs to determine.

Step 6

Building permit and plan review, plus the separate trade permits

Comment and resubmittal cycles are normal and are usually driven by gaps in the product listing documentation rather than by the structure. Electrical, mechanical and plumbing are separate permits and separate licensed trades. Septic and well separation runs through the county health department and is highly local.

Step 7

Inspections, including the one everybody forgets

Rough-in inspections for electrical and mechanical, and the anchorage inspection before backfill. Backfilling before the anchorage inspection means excavating again, at the contractor's cost and the customer's patience. Put it on the programme in bold and say it out loud at the pre-construction meeting.

Step 8

Commissioning, handover, and the first moment a compliance statement becomes possible

FAT → SAT → single-system commissioning → integrated test with deliberate fault injection → 72-hour occupied trial, then the ongoing service obligation. This is the first point at which any compliance statement becomes possible, and only because the Authority Having Jurisdiction has accepted the work. Not at quotation, not at delivery, not at installation.

Who signs what. Show this table to the customer — it is deliberately conservative about what the factory will put its name to.
DeliverableFactoryLocal agentCA-licensed PE or architectAHJ
Product design, fabrication, factory QAOwns———
Test reports with standard, edition, laboratory, specimen configuration, installation condition and validityOwnsDelivers unalteredReviewsReviews
Statement of design basis and explicit limitations — what the product does not doOwnsPresents unaltered——
Jurisdiction, governing code edition, AHJ identificationSupportsOwnsConfirmsConfirms
Geotechnical investigation; site-specific structural design, anchorage, buoyancy, flood siting—CoordinatesOwns and sealsApproves
Permit application, drawings, calculations, stamped submittal—SupportsOwns the sealDecides
Field modification, new penetration, component substitutionFormal change control — approval requiredMust refuse unapproved changesRe-analyses and re-sealsRe-inspects
Final acceptance and legal compliance determination——Certifies the designOwns — sole authority
Read that table with the status page open

Owns in the factory column means the party who will be accountable for that deliverable when a product exists. It is not a claim that the document exists today. At this revision we hold no test report, no product listing and no certified anchorage detail of our own; under the basic concept those originate with the tested and listed shell and door supplier, and a supplier who cannot produce them is a No-Go under our own criteria. An agent who shows this table to a customer must say that sentence out loud rather than letting the table imply otherwise.

The factory owns this — and nothing beyond it
  • Shell and module design intent, and fabrication to a frozen specification.
  • Factory acceptance testing, material and weld traceability, coating records.
  • Formal change control. Doors, frames, hardware and anchorage are a tested assembly and are not substituted in the field.
  • The commissioning protocol: airtightness, airflow, pressure differential, monitoring calibration, black start, dual-exit drill, and the 72-hour occupied trial.
  • An owner's manual stating applicable threats, prohibited uses, maximum occupancy, maximum occupancy duration, maintenance intervals and evacuation conditions.
The factory does not own this — and saying otherwise is the breach
  • Any California compliance claim, and any statement that a product complies with a code edition.
  • The geotechnical report, the structural seal and the flood siting determination. Those belong to professionals licensed in California.
  • The defensible space and Zone 0 obligation, which stays with the property owner for as long as they own the property.
  • The permits and the inspections. Those belong to the jurisdiction, which endorses neither a product nor a brand and never will.
  • Any statement about an insurance outcome. That belongs to the carrier, in writing, before the customer buys.
The agent's real job, stated commercially

Construction work in California is licensed by the Contractors State License Board, and a partner who installs generally needs a licence or must subcontract to one; a partner who only introduces does not. Verify the current CSLB threshold and classification for the work you intend to do — do not take it from this page. We recommend two tiers: a Referral Agent who introduces and pre-screens against the site-exclusion checklist and never quotes performance, compliance or an insurance outcome; and an Accredited Installing Partner who holds the licence, carries the permit relationship, and signs the change-control undertaking.

On margin, we deliberately recommend against the distribution benchmarks common in US building products. For a low-volume, high-liability engineered product the value a partner adds is documentation, permit navigation and installed quality — not stocking risk. 15–25% on installed contract value, plus a separately invoiced engineering-and-permit facilitation fee, plus a commissioning fee aligns the partner's income with the things that actually determine whether the project completes. The maintenance and filter-change contract is where the recurring revenue lives, and it is also the only mechanism that keeps the product working in year five.

CW-06Fit and next step

Which tier, which buyer, and how to lose the wrong one quickly

Qualify before quoting

A bad-fit buyer costs more than a lost one: months of consultant fees, a refused permit, and an agent's standing in a county where every fire-safe council member knows every other one. The questions below are built to disqualify fast. Ask them in this order, before the budget conversation, and be willing to end the call on any of them.

S1

The only tier in this conversation

A transportable single-cabin basic product, derived by subtraction from the master architecture. Targeted at filtered air against smoke and a short wait-for-rescue period. Independent air treatment is mandatory in it, not an upgrade. Preferred configuration is at-grade or semi-buried. Area, occupant count and duration: TBD, by site calculation.

Concept feasibility only
S2 / S3

Not on the table for this hazard

The mid and master tiers exist, and their capital cost is not estimable at this revision. If a wildfire prospect is being shown a master architecture, someone has mistaken a hazard for an aspiration. Bring the conversation back to the assessed hazard zone, the catchment above the house, and the permit route.

Neither

In California this is usually the right answer

For most interface households the higher-value spend is the roof, the vents, the glazing, the decking, the first five feet, and a CARB-certified air cleaner sized to a room. Saying so costs one sale and earns the referrals. Declining a site is the credibility asset — it is the only thing on this page a competitor cannot copy cheaply.

01What is your trigger to leave, who executes it, and is there a second route off the property?

Ask this first, before the budget. CAL FIRE's guidance is not to wait for an order. If the household has no written trigger and no second route off the lot, send them to the agency's evacuation resources and do not quote yet. A refuge sold to a household without a leave plan has been sold into the exact failure mode the fire services warn about.

02Are you calling because of an insurance letter?

Usually the answer is yes, and the honest response is that this product does not fix that. We are not insurance advisers, we have found no evidence that a shelter by itself changes a California homeowners rating, and an unpermitted structure can make a claim or a sale harder rather than easier. What a shelter addresses is a habitability problem during smoke and a shutoff. If the customer's actual problem is the premium, the useful referral is a broker and a mitigation programme, not us.

03Has the catchment above your house burned in the last several years?

If yes, a below-grade refuge is probably a No-Go this year and possibly for several. Debris-flow-initiating rainfall has a return period close to one year immediately after a fire, easing toward more than ten years only after roughly four seasons of vegetation recovery. Offer a written revisit date rather than a discount. A parcel that was fine in the geotechnical report before the fire is a different parcel now.

04Is the site in a mapped floodway, a FEMA Zone V, a mapped Coastal A Zone or a landslide zone?

Any of these is a No-Go or relocate under our own gate criteria, and FEMA's siting criteria are explicit that safe rooms are not allowed in floodways under any circumstance. This is not negotiable, it is not priced around, and it is not solved by a thicker shell. End the conversation or move the position on the lot.

05Is anyone in the household on powered medical equipment, or on the utility's medical baseline programme?

This is the strongest genuine fit signal on the page, and it is the one a good agent should actually chase. An oxygen concentrator, a CPAP, a nebuliser or refrigerated medication turns a shutoff from an inconvenience into a clinical problem, and the shutoff lands on the same days as the smoke. Note the counterweight: the CDC and fire agencies advise that people with respiratory or cardiovascular illness should be away from the threat where possible, rather than relying on staying. Say both halves.

06Has the house itself been hardened, and is the first five feet clear?

If the roof, vents, glazing and decking have not been addressed and Zone 0 is untouched, the customer is about to spend six figures on the least likely harm pathway while leaving the most likely one open. Send them to do that work first. You will lose twelve months of pipeline and gain a customer who arrives already trusting you — and who has a much better chance of a permit.

07Who is your California-licensed engineer, and will this jurisdiction accept a below-grade habitable structure here?

The binding constraint is a licensed professional willing to seal a first-of-type design and a plan checker willing to review it. Book the pre-application meeting before the deposit, not after. A no in week one is cheap; a no in month nine has already consumed a geotechnical report, a structural fee and the customer's goodwill.

08What budget does the household have in mind?

The only figure we may quote is the S1 concept budget: USD 180,000 target against a USD 200,000 cap — a concept budget that excludes land, abnormal geotechnical conditions, major retaining works, long utility runs, import duties and significant site remediation, and that must be re-validated against local Californian shell, door, anchorage and labour quotations before it reaches a buyer. California labour, seismic design and permit costs will move it, and they will not move it down.

Say the gap out loud. A household anchored in the low tens of thousands is not a bad customer; they are simply not a customer for this product, and for that budget the hardening-plus-air-cleaner route genuinely does more for them. Pretending otherwise wastes their money and your months.

If local pricing pushes life-safety items past the cap, the response is to reduce scale or move to a smaller tested and listed prefabricated unit — never to cheapen the doors, the anchorage, the ventilation, the smoke and CO monitoring, the emergency lighting or the professional review. Those are the items our own baseline forbids cutting.

09Is the customer actually asking for flame immersion, long-term underground living, or radiation protection?

Then the basic route is void. Under our own Go/No-Go rules the requirement returns to the master architecture for a full redesign, and master-tier capital cost is not estimable at this revision. Do not sell the basic product into that brief with a reassuring adjective attached to it.

10Who will maintain it and drill it, every year, for as long as they own the property?

Filters changed on schedule and more often during smoke episodes. Monitoring instruments calibrated. Main entrance sealed. Grid power lost. Hand-crank ventilation at full occupancy against a loaded filter. Everybody out through the secondary exit. A refuge that is not maintained and not drilled is a room, not a life-safety system — and the maintenance contract is where the agent's recurring revenue lives. A customer who will not commit to the drill has told you what the product will be worth on the day.

The status this page is sold under

Concept feasibility is conditional go. Design freeze, construction permit and master-tier capital cost are no-go or not estimable. Decision gates G0 through G6 remain not passed, without exception, and construction is not authorised. The S1 concept budget is the only price on this page, and it is a concept budget requiring local re-validation. Anyone who tells a Californian prospect otherwise is not shortening the process — they are ensuring it ends at the plan-check counter.

The next step, in the order it happens
  • Plan first. Send the household to CAL FIRE's evacuation resources. Confirm a written leave trigger and a rehearsed second route off the lot before anything else is discussed.
  • Harden the house and clear the first five feet. This outranks the shelter on cost-effectiveness for almost every interface household, and a permit conversation goes better when the property already looks like the owner takes it seriously.
  • Pre-screen the site against the No-Go list — mapped floodway, Zone V, mapped Coastal A, landslide zone, burned catchment above the position, no apparatus access, no crane or excavator route. This is a site visit, not a form.
  • Book the pre-application meeting with the building department and the fire authority, and establish in writing whether a below-grade habitable structure is reviewable here in the first place. Do this before the deposit.
  • Commission the geotechnical investigation once the site survives screening. Nothing downstream can be sealed without it, and nothing should be quoted as a depth or a thickness before it exists.
  • Re-validate the concept budget against local Californian shell, door, anchorage, seismic design and labour quotations before it is shown to the household as a number.
  • Make no compliance claim, and no insurance claim, at any point before the Authority Having Jurisdiction accepts the finished installation and before the carrier has answered in writing. Not at quotation, not at delivery, not at installation.

Top ↑