Module register23 modules, one naming system
Select a module to see what it is responsible for, and whether it survives into the smaller tiers. These identifiers run through the drawings, the spare parts, the work orders and the maintenance log — the same numbers, not a marketing taxonomy.
M01Every tier
Main entrance & security check
A protected or concealed surface entrance, with the protective door separate from the everyday door, and mechanical release from both sides.
M02S3 / tier-dependent
Detection, decontamination & airlock
A one-way contamination corridor: outer check, survey, doffing, dry decontamination, shower, re-survey, clean change, medical observation. Nobody arriving from outside crosses the clean living zone.
M03S3 / tier-dependent
Command, AI & routine maintenance
Local survival guidance, whole-shelter condition monitoring, work orders, offline manuals — and a manual broadcast and mechanical control fallback for when it fails.
M04S3 / tier-dependent
Living & sleeping
Zoned sleeping, acoustic and visual privacy, a lighting rhythm that holds a circadian cycle underground, and step-free access for stretchers.
M05S3 / tier-dependent
Kitchen, food & controlled growing
Long-term stores on first-in-first-out rotation, low-energy cooking, dedicated extract, and a kitchen that can be shut down and isolated in a fire.
M06S3 / tier-dependent
Medical, observation & biocontainment
Several independent isolation rooms, each with its own anteroom and closable boundary, held at controlled negative pressure with dedicated exhaust that never returns to the clean zone.
M07Every tier
Air life support
Every tier has this. Pre-filter, particulate filter, gas-phase filter, slight overpressure, blast and isolation valves — plus a DC backup fan and a hand or foot crank that works with no power at all.
M08S3 / tier-dependent
Water treatment, storage & reclamation
Two-valve manual isolation of the external supply, separated raw, potable, greywater and reclaimed stores, and a multi-barrier train whose product water cannot reach the potable tank without passing a quality interlock.
M09Every tier
Sanitation & wastewater
Manual closure and physical isolation of the external sewer, backflow prevention, duty and standby lift pumps, and enough storage to stay closed.
M10Every tier
Energy & distribution
Grid, UPS, battery, two independent diesel sets, wind, solar, supercapacitor buffering and a low-voltage DC life-safety bus — with manual bypass and black start.
M11S3 / tier-dependent
Plant & maintenance
Fans, pumps, valves, controllers and spares in one place, high-risk plant separated from living space, and the ability to complete the main repairs without entering a contaminated zone.
M12Every tier
Stores
Food, potable water, medical supplies, protective equipment, spares, cleaning stock, emergency tools — and dangerous goods stored apart.
M13Every tier
Main escape route
Mechanically openable without power, smoke and water protected, wide enough for a stretcher.
M14Every tier
Remote secondary exit
Does not share a shaft with the main entrance and surfaces in a different collapse-risk zone, with its own lighting, drainage, comms and air testing.
M15Every tier
Communications & data
Fibre, copper, Wi-Fi and satellite, on physically separated paths with separated antennas — and a wired intercom that keeps working when all of it is gone.
M16S3 / tier-dependent
Radiation monitoring room
Two independent instruments — one fixed and continuous, one portable for cross-checking — which may not share a single power source, charger or data terminal.
M17S3 / tier-dependent
Independent HVAC for critical zones
No whole-building shared return. Decontamination and biocontainment zones never return air to the clean side, and any one zone can be isolated without shutting down shelter-wide life support.
M18S3 / tier-dependent
Biological & chemical incident support
Screening, triage, exposure logging, observation, isolation, waste handling and release — as a written process, with AI assisting the checklist and a person making the medical call.
M19S3 / tier-dependent
Controlled hydroponics (candidate)
Under study, and deliberately not a life-safety system. It provides leafy greens, herbs and routine — never the oxygen supply, never the CO₂ removal, never the staple food.
M20S3 / tier-dependent
Smoke control & clean-air refuge
A dedicated smoke exhaust path to the surface, plus an independent refuge room with its own air handling, overpressure and short-term breathing-air reserve.
M21S3 / tier-dependent
Low-voltage room & outdoor awareness
Visible-light, low-light and thermal cameras distributed so that losing the main entrance still leaves eyes on the secondary exit, with recording held locally.
M22S3 / tier-dependent
Dedicated fire control room
Physically and fire-separated from plant, fuel and contaminated zones, with hardwired manual panels — never AI, Wi-Fi or a single touchscreen as the only way to operate it.
M23S3 / tier-dependent
Geothermal, GSHP & dedicated well
Closed-loop preferred. The drinking-water well and the heat-pump abstraction and recharge wells are designed separately and are not assumed to be shared.